PRINTED FROM AMA MANUAL OF STYLE ONLINE (www.amamanualofstyle.com). © American Medical Association, 2009. All Rights Reserved. Under the terms of the license agreement, an individual user may print out a PDF of a single chapter of a title in AMA Manual of Style Online for personal use (for details see Privacy Policy). 

Subscriber: null; date: 23 July 2016

Pacemaker Codes

The capabilities and operation of cardiac pacemakers are described by 3- to 5-letter codes.6,7

DDIR pacing

VVI pacemaker

The code system for antibradycardia pacemakers endorsed by the North American Society of Pacing and Electrophysiology and the British Pacing and Electrophysiology Group is known as the NASPE/BPEG Generic Code or NBG Code. Although the code need not be expanded when mentioned in passing, it is good practice to describe pacing modes in prose at first mention, eg, “dual-chamber, adaptive-rate (DDDR) pacing.” The NBG Code was revised in 2001 to apply to antibradycardia, adaptive-rate, and multisite pacing.8,9

In Table 1, positions I through V refer to the first through fifth letters of the NBG Code. The character for “None” is the letter O, not the numeral 0. In practice, the first 3 positions are always given; the fourth and fifth are added when necessary to provide additional information.

Table 1. Revised NASPE/BPEG Generic Code for Antibradycardia Pacinga

Position

I

II

III

IV

V

Category

Chamber(s) Paced

Chamber(s) Sensed

Response to Sensing

Rate Modulation

Multisite Pacing

O = none

O = none

O = none

O = none

O = none

A = atrium

A = atrium

T = triggered

R = rate modulation

A = atrium

V = ventricle

V = ventricle

I = inhibited

V = ventricle

D = dual (A + V)

D = dual (A + V)

D = dual (T + I)

D = dual (A + V)

Manufacturers’ designation only

S = single (A or V)

S = single (A or V)

a Reprinted, with permission, from Bernstein et al.8

Note: The principal changes from the previous (1987) code are the dropping of classifications from position IV (P, simple programmatic; M, multiprogrammable; C, communicating) and additions to position V (shown in the table) and deletions from position V (P, pacing; S, shock). Position V, which formerly applied to antitachyarrhythmia functions, now applies to multisite pacing.